Korea University(KU) has installed 14 GHz Electron Cyclotron Resonance Ion Source (ECRIS) for researches on material science and bio science. The high voltage platform of KU-ECRIS had been upgraded form 10kV to 30kV. During the upgrade, the geometry of the plasma electrode is changed due to arc discharge occurred in cone-shaped plasma electrode. According to positions of plasma electrode, effects of the total current and currents of multi charged ions were investigated. The informations about position of plasma electrode and beam size were obtained using SIMION simulations. The comparison of experimental results between total current and current of multi charged ions with two faraday cups will reported in this paper. We will introduce currents status of beam measurements for the KU-ECRIS.
● This work was supported by the national Research Facilities and Equipment Center (NFEC) grant funded by Korean Government (Ministry of Education) (Grant No. 2019R1A6C1010027).